Electric Motor Service Factor

Motor Service Factor Sf Is The Percentage Of Overloading The Motor Can Handle For Short Periods When Operating Normally Within T Motor Electric Motor Factors

Motor Service Factor Sf Is The Percentage Of Overloading The Motor Can Handle For Short Periods When Operating Normally Within T Motor Electric Motor Factors

New A O Smith St1072 3 4 Hp 3450 Rpm 1 5 Service Factor 56j Frame Capacitor Start Odp Enclosure C Face Pool Motor Online Shopping Newclothingtrendy In 2020 Pool Pump Electric Motor Electric Motor For Bicycle

New A O Smith St1072 3 4 Hp 3450 Rpm 1 5 Service Factor 56j Frame Capacitor Start Odp Enclosure C Face Pool Motor Online Shopping Newclothingtrendy In 2020 Pool Pump Electric Motor Electric Motor For Bicycle

Century Usq1152 1 1 2 Hp 1 1 Service Factor 48y Frame Capacitor Start Capacitor Run Odp Enclosu Electric Motor For Bicycle Pool Pump Electric Motor For Car

Century Usq1152 1 1 2 Hp 1 1 Service Factor 48y Frame Capacitor Start Capacitor Run Odp Enclosu Electric Motor For Bicycle Pool Pump Electric Motor For Car

A O Smith Sq1152 1 1 2 Hp 1 47 Service Factor 48y Frame Capacitor Start Capacitor Run Odp Enclosure Squar Pool Pump Will Smith Electric Motor For Bicycle

A O Smith Sq1152 1 1 2 Hp 1 47 Service Factor 48y Frame Capacitor Start Capacitor Run Odp Enclosure Squar Pool Pump Will Smith Electric Motor For Bicycle

Pin On Electrical Equipment

Pin On Electrical Equipment

A O Smith Cp1102l 1 Hp 3450 Rpm 115 230 Volts 1 Service Factor Reversible Rotation 5 8inch By Electric Motor For Bicycle Electric Motor For Car Electric Motor

A O Smith Cp1102l 1 Hp 3450 Rpm 115 230 Volts 1 Service Factor Reversible Rotation 5 8inch By Electric Motor For Bicycle Electric Motor For Car Electric Motor

A O Smith Cp1102l 1 Hp 3450 Rpm 115 230 Volts 1 Service Factor Reversible Rotation 5 8inch By Electric Motor For Bicycle Electric Motor For Car Electric Motor

Motor service factor is probably the most misunderstood value on a motor nameplate.

Electric motor service factor.

To most it seems quite simple. Likewise for each power and speed the mg 1 standard defines a frame number which is linked to the service factor. The reference point is a service factor of 1 which would mean a motor cannot operate over its rated horsepower or hp without overheating. The service factor sf is commonly misunderstood as an allowable overload for electric motors for example you may find a 100 hp motor with a sf of 1 15 driving a 110 hp load under the incorrect assumption that it tolerates up to 115 hp.

Typical service factors sf for ac motors. The service factor sf is a measure of periodically overload capacity at which a motor can operate without damage. In the u s the defacto standard for ac motors is the nema standards. 1 15 x 1 1 15hp anything above this load will certainly result in motor overheating and consequent damage of the ac motor.

The canadian electrical code defines service factor as a multiplier that when applied to. A service factor or sf is a factor representing the capacity at which a motor can operate without overloading or damaging its core or components. For example the maximum motor load for a 1hp electric motor with a service factor of 1 15 is. Traditionally totally enclosed fan cooled tefc motors had an sf of 1 0 but most manufacturers now offer tefc motors with service factors of 1 15 the same as on odp motors.

Most hazardous location motors are made with an sf of 1 0 but some specialized units are available for class i applications. The nema national electrical manufacturers association standard service factor for totally enclosed motors is 1 0. Motors of 10 hp and up usually have a service factor of 1 15. When the motor is operated at any service factor greater than 1 it may have efficiency power factor and speed different from those at rated load but the locked rotor torque and current and breakdown torque will remain unchanged.

A motor operating continuously at any service factor greater than 1 will have a reduced life expectancy compared. A motor operating continuously at a service factor greater than 1 will have a reduced life expectancy compared to operating at at its rated nameplate horsepower. Most motors have a duty factor of 1 15 for open motors and 1 0 for totally closed motors. As per the standards a motor s nameplate should indicate the service factor as sf.

The rated horsepower of an ac motor to the rated armature current of a dc motor or.

A O Smith B2853 1 Hp 3450 Rpm 1 Speed 230 115 Volts 6 6 13 2 Amps 1 25 Service Factor 56y Frame Psc Odp With Images Pool Pump Spa Pool Electric Motor For Bicycle

A O Smith B2853 1 Hp 3450 Rpm 1 Speed 230 115 Volts 6 6 13 2 Amps 1 25 Service Factor 56y Frame Psc Odp With Images Pool Pump Spa Pool Electric Motor For Bicycle

A O Smith H885l 56 1 1 2 Hp 1725 Rpm Odp Enclosure 56hz Frame 1 15 Service Factor Frame General Purpose Motor A Electric Motor For Bicycle Motor Fan Motor

A O Smith H885l 56 1 1 2 Hp 1725 Rpm Odp Enclosure 56hz Frame 1 15 Service Factor Frame General Purpose Motor A Electric Motor For Bicycle Motor Fan Motor

Advertisement Ebay 500 Hp Marathon Electric Motor 1800 Rpm 5011ls Frame Teao 460v Electric Motor Marathon Motors Motor

Advertisement Ebay 500 Hp Marathon Electric Motor 1800 Rpm 5011ls Frame Teao 460v Electric Motor Marathon Motors Motor

575v 1 780 Rpm 3 Phase 60 Hz Frame 447tz 178 7a 1 15 Service Factor Please Contact Us For More Information Electric Motor Hyundai Electricity

575v 1 780 Rpm 3 Phase 60 Hz Frame 447tz 178 7a 1 15 Service Factor Please Contact Us For More Information Electric Motor Hyundai Electricity

Source : pinterest.com